EFFECTIVE DATE:
REPLACES:
BRYAN BOILERS
O
R
D
E
R
N
O
.
:
PERU, INDIANA 46970
783 NORTH CHILI AVE
FORM NO.:
2167
RV-KD SERIES FORCED DRAFT
WATER BOILERS (RV450-RV800)
CONSULT FACTORY FOR BURNER EXTENSION APPLICATIONS
INCHES. THOSE IN PARENTHESES
ARE ALL ±1/2".
ARE CENTIMETERS.
CERTIFIED DIMENSIONS.
CONSULT FACTORY FOR
SPECIFICATIONS & CONDITIONS.
VARY DEPENDING ON JOB
BURNER CONFIGURATION WILL
3. GAS TRAIN, CONTROL AND
2. LOCATION DIMENSIONS
TO CHANGE WITHOUT NOTICE.
4. DIMENSIONS ARE SUBJECT
1. ALL DIMENSIONS ARE IN
NOTES:
3/22/04
5. CONTROL TAPPINGS 3/4" NPT
2. FORCED DRAFT BURNER
3. RELIEF VALVE'S
1. PROBE TYPE L.W.C.O.-
17. COMB. CHAMBER DRAIN 1" NPT
16. FLAME OBSERVATION PORT
15. HEIGHT OVER SUPPLY
14. HEIGHT OVER JACKET
13. DRAIN CONNECTION 2" NPT
10. VENT CONNECTION 1" NPT
12. LIFTING LUGS
11. OIL PUMP LOCATION
4. BURNER CENTER LINE
9. ELEC. ENCLOSURE-
8. CLNOUT./INSP. OPNG.-1 1/2"NPT
7. PRESS./TEMP. GAUGE
6. JACKET ACCESS PANELS
ORDER REV. NO.:
A-LENGTH OVER JACKET
(442.2)
174 1/8"
(47.6)
18 3/4"
(384.4)
(40.6)
16"
(15.2)
6" FLG
(15.2)
6" FLG
(417.6)
164 7/16"
(40.6)
16"
(47.6)
18 3/4"
(360.0)
H-BURNER EXTENSION
B-FLUE LOCATION
C-FLUE DIAMETER
D-LENGTH OVER BASE
G-SUPPLY / RETURN NOZZLE SIZE
(628.7)
247 1/2"
(499.4)
196 5/8"
(474.9)
187"
(50.8)
20"
(52.7)
20 3/4"
(40.6)
16"
(47.6)
18 3/4"
(555.9)(441.6)(417.1)
(40.6)
16"
(47.6)
18 3/4"
(15.2)
6" FLG
(15.2)
6" FLG
(15.2)
6" FLG
(15.2)
6" FLG
(52.7)
20"
(50.8)
(498.7)
20 3/4"
225 7/8"
(573.7)
RV500
151 3/8"
RV450
141 3/4"
BOILER MODEL
RV800RV600RV550
218 7/8"173 7/8"164 1/4" 196 3/8"
RV700
16
13
REAR VIEW
17
14
87 9/16"
(222.4)
8
89 3/4"
(227.9)
LEFT SIDE VIEW
6
33 1/2"
(85.1)
4
FRONT VIEW
8
11
CENTER LINE.
FLANGES TO STRADDLE
5. ALL FLANGES ARE 150#
UNLESS OTHERWISE NOTED,
(22.2)
8
RETURN
15
G
8 3/4"
21 3/8"
50"
(127.0)
(54.2)
10
PLAN VIEW
3
5
12
SUPPLY
G
7
A
6 1/2"
(16.5)
25 5/8"
B
(65.0)
C
MINIMUM TUBE
REMOVAL CLEARANCE
2
(81.3)
32"
1
9
SERVICE AREA
(121.92)
48"
BURNER
H
D
8/11/03
Vue de la page 0
1 2

Résumé du contenu

Page 1 - BRYAN BOILERS

EFFECTIVE DATE: REPLACES: BRYAN BOILERS ORDER NO.:PERU, INDIANA 46970783 NORTH CHILI AVEFORM NO.:2167RV-KD SERIES FORCED DRAFTWATER BOILERS (RV450-RV8

Page 2 - KNOCKDOWN WATER BOILERS

BRYAN BOILERSRV SERIES FORCED DRAFTKNOCKDOWN WATER BOILERSForm # >> 2167Date >> 9/5/2003BOILER MODEL RV450 RV500 RV550 RV600 RV700 RV800

Commentaires sur ces manuels

Pas de commentaire